957RPDA
Reduced Pressure Detector Assembly Backflow Preventers with Flood Sensor, Stainless Steel – Sizes 2 1/2 - 10 IN
Series 957RPDA reduced pressure detector assemblies feature a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. Activated through an add-on connection kit, the sensor can trigger the alert system sending notification of flood detection to facility personnel. Connection kits are available for BMS and cellular communication.
This series help stop the reverse flow of fire protection system substances being pumped or siphoned into the potable water supply. A meter incorporated to detect ground leaks and unauthorized illegal taps greatly reduces annual water expenses. Check with local water authorities for installation requirements.
To learn more visit: https://www.watts.com/floodprotectionsystem
Features
- Sensor on the relief valve for flood detection
- Extremely compact stainless steel body with stainless steel internal parts
- Ideal for health hazard cross-connection such as on fire sprinkler systems
- Available with quarter-turn ball valve shutoffs or grooved butterfly valve shutoffs
- Torsion spring checks providing the lowest pressure loss
- Lightweight stainless steel construction (70% lighter than traditional designs)
- Flood alert feature activated with add-on connection kit, compatible with BMS and cellular communication
Literature
-
- 957, 957RPDA, LF957RPDA - Repair Kits Parts Breakdown
- Brochure - Backflow Prevention and Flow Control Plumbing
- Brochure - Backflow Protection with Series 957-FS, 957RPDA-FS, LF957RPDA-FS
- Flyer - Flood Detection for RPZ/RPDA Backflow Preventers with Flood Sensor
- Flyer - Flood Detection for RPZ/RPDA Backflow Preventers with Flood Sensor (French)
- Installation Instructions - 957, 957RPDA, LF957RPDA
- Installation Instructions - BMS Flood Sensor Connection Kit
- Installation Instructions - BMS Sensor Retrofit Connection Kit - 994, 957, 957RPDA, LF957RPDA, C400, C500, LFC500, 4000SS, 5000SS
- Installation Instructions - Cellular Flood Sensor Connection Kit
- Installation Instructions - Cellular Sensor Retrofit Connection Kit - 994, 957, 957RPDA, LF957RPDA, C400, C500, LFC500, 4000SS, 5000SS
- Price List - Backflow Prevention Repair Kits & Service Parts
- Specification Sheet - 957RPDA
- Specification Sheet - 957RPDA (French)
- Specification Sheet - 957RPDA (Spanish)
- Specification Sheet - Flood Sensor Connection Kit - Watts
- Specification Sheet - Flood Sensor Connection Kit - Watts (French)
- Specification Sheet - Flood Sensor Connection Kit - Watts (Spanish)
Select a Model
Select options below to identify the UPC, Order Code, and Repair Kit for a specific 957RPDA
No results found
Share this Product
Approval/Certification Information
For product-specific approval information, please refer to the product’s specification sheet (see literature section above) or ask a Watts representative. For general information regarding any approval certification partners identified in the specification sheet, please visit our certification partners’ websites:
ASSE | CSA | FM Approvals | NSF |
UL | ULC | USC | WQA |